Tenerife Drilled to 9,843 ft (3,000 m) and Found Heat, Water and Permeability. Now the Wells Have to Prove the Resource

Writer: Juan Carlos Beltrán
Juan Carlos Beltrán
Oct 24
9 min read

Updated: Oct 29

Heat, subsurface fluids, and permeability have been confirmed beneath Vilaflor, with elevated pressure and high temperatures also reported. The next wells and tests will determine whether those indications add up to a geothermal reservoir that can be produced sustainably for decades.


Executive Summary

In September 2026, the deep geothermal exploration well at Vilaflor, Tenerife, reached about 9,843 ft (3,000 m) after roughly four months of drilling. Spain's Ministry for the Ecological Transition (MITECO) describes it as the first deep geothermal borehole in the country's history and the deepest geothermal exploration carried out in the Canary Islands, and therefore in Spain, since the 1970s. The project is run by Energía Geotérmica de Tenerife, a public-private consortium formed by the Cabildo de Tenerife, DISA and Reykjavík Geothermal. MITECO reported high-pressure fractures and temperatures above 212 °F (100 °C), while La Gaceta de Canarias reported temperatures above 302 °F (150 °C) at 9,843 ft (3,000 m) together with water, pressure, and permeability.


Some headlines described the finding as water in an unprecedented state. The reality is simpler and more useful. At sufficient pressure, water can remain liquid well above its atmospheric boiling point. In a conventional hydrothermal system, that hot fluid is the medium that carries heat through permeable rock and fractures and, if the resource proves commercial, towards the surface.


The result is encouraging, but it remains an exploration result. The project team has repeatedly called for caution: productive capacity has not yet been established, two additional exploration wells are planned, and La Gaceta de Canarias reported that the consortium expects to know whether the potential is confirmed during the first half of 2027. For PES, the case is especially relevant because it sits at the intersection of groundwater, geothermal energy and deep well engineering.


1. What the Vilaflor Well Found

The Vilaflor project has €14.5 million in NextGenerationEU funds from the Recovery Plan, granted under VIAGEO, IDAE's incentive programme for deep geothermal exploration. According to MITECO, it is the most advanced of the nine projects the programme supports in the Canary Islands, which together receive just over €100 million and are distributed across Tenerife, La Palma and Gran Canaria.


The technical significance is the combination of indicators. MITECO reported high-pressure fractures and temperatures above 212 °F (100 °C), indicating a pressurised hydrothermal zone. The Cabildo, through ITER, confirmed favourable indications of temperature, pressure and permeability, including hot water at elevated pressure. La Gaceta de Canarias also reported temperatures above 302 °F (150 °C). Reykjavík Geothermal's CEO, Magnús Ásbjörnsson, described the indications as promising but emphasised that the resource still has to be characterised.


La Gaceta de Canarias also reported that preliminary geochemical analyses by Involcan suggest a meteoric origin for the water, meaning rainfall that infiltrated the volcanic edifice rather than seawater. If confirmed, that would be consistent with deep hydrothermal circulation in which meteoric water moves down through faults and fractures, gains heat at depth, and becomes part of a pressurised subsurface system.


2. Where Groundwater and Geothermal Systems Meet

This is where the water and geothermal sides of the story come together. In a conventional hydrothermal system, groundwater circulating through permeable rock or fractures transports heat. Many of the same questions asked in deep groundwater projects also matter here: where the fluid comes from, how the system is recharged, how connected the fractures are, and how pressure responds when fluid is produced. Figure 1 shows the concept in simplified form.


Conceptual sketch of hydrothermal circulation beneath a volcanic island: rainfall infiltrates, moves down through faults, heats at depth and forms a pressurised fluid reached by the Vilaflor well.
Figure 1. Conceptual hydrothermal circulation beneath a volcanic island. Not to scale.

Geothermal fluids add another layer of complexity. Mineral content, dissolved gases, scaling tendency and corrosivity influence casing, cement, completion materials and surface facilities. A meteoric origin does not by itself mean the fluid is fresh or suitable for consumption. Only complete chemical and isotopic characterisation can define its composition and behaviour.


For that reason, it would be premature to describe the Vilaflor finding as a new drinking-water resource. The water is important because it carries heat. If the project advances, fluid production, treatment requirements and reinjection strategy will form part of reservoir management and long-term resource sustainability.


3. The Drilling Story Behind the Result

The subsurface result has attracted most of the attention, but the drilling programme deserves the same. ThinkGeoEnergy reported good temperature and permeability indicators, including about 302 °F (150 °C) at around 7,546 ft (2,300 m), while drilling was still progressing towards the 9,843 ft (3,000 m) target. Atlántico Hoy reported that the well crossed very hard volcanic rock between roughly 3,281 and 6,562 ft (1,000 and 2,000 m), with values of 8 to almost 9 on the Mohs scale, and that some steel and tungsten-alloy bits failed during drilling. By September, the well had reached about 9,843 ft (3,000 m), and the hydrothermal indicators were being evaluated.


From a well-engineering perspective, volcanic geothermal drilling can involve hard and abrasive formations, fractured intervals, severe lost circulation, and high temperatures that affect drilling fluids, downhole tools, electronics, cement, and long-term well integrity. The same fractures that may provide reservoir productivity can also become major loss zones while drilling. Depending on the pressure regime and loss behaviour, aerated fluids, stable foams or other pressure-management approaches may be considered as part of the drilling strategy.


Some operational details have been published. Robit, the manufacturer of the hammer used on the project, reported that the drilling contractor is the British company Marriott Drilling Group and that the conductor was drilled with a pneumatic drilling hammer and a 30 in (762 mm) casing system. The conductor was set at about 131 to 197 ft (40 to 60 m) and cemented to surface, through weathered and fractured rock and clay, with a sudden change to very hard rock from about 148 ft (45 m). On the second well, drilling stopped at 197 ft (60 m) when a component of the drilling assembly failed. According to Robit, the deeper sections were planned with standard oilfield drilling techniques. Tenerife Weekly reported crews from more than 20 countries working around the clock and €28.8 million for drilling the three planned wells. That outlet rated the rock at 7 on the Mohs scale, while Atlántico Hoy reported 8 to almost 9 between 3,281 and 6,562 ft (1,000 and 2,000 m).


No public information was found on the drilling fluids used below the conductor, on lost circulation events, on the casing programme, or on the rig. In a fractured volcanic section, those are exactly the questions a drilling engineer would put to the operator: whether losses were partial or total, whether the hole was drilled with water, mud, aerated fluid or foam, how the loss zones were handled and how the casing seats were chosen. For the next two wells, those answers will matter as much as the reservoir data.


4. A Note on the Numbers

The temperature figures require careful reading. MITECO reports temperatures above 212 °F (100 °C). La Gaceta de Canarias reported temperatures above 302 °F (150 °C), while ThinkGeoEnergy had already reported about 302 °F (150 °C) at around 7,546 ft (2,300 m) before the well reached final depth. These are encouraging indications, but they are not a substitute for stabilised temperature surveys and reservoir testing. Table 1 summarises what has been reported, by whom and with what status.


In geothermal practice, resources and wells are classified as low, medium or high enthalpy, although the thresholds are usually expressed as reservoir temperature, with high enthalpy often placed above about 302 °F (150 °C). The limits vary between authors and countries. For liquid water, enthalpy depends almost entirely on temperature, and the big difference comes from the phase: saturated liquid water at 302 °F (150 °C) carries about 272 Btu/lb (632 kJ/kg), against roughly 1,180 Btu/lb (2,750 kJ/kg) for saturated steam. That explains why the figures reported at Vilaflor are temperatures. The enthalpy classification of the resource will depend on what testing confirms about temperature and fluid phase.


According to Atlántico Hoy, the project also reported a pressure of almost 435 psi (30 bar). Public reporting does not specify the measurement point, the test condition, or whether the figure refers to wellhead, flowing, or downhole pressure. It should therefore not be interpreted as reservoir pressure without operator data. That distinction matters because pressure behaviour, together with temperature and flow rate, will determine how the system can actually produce. Figure 2 adds a physical reference: under pressure, water stays liquid far above 212 °F (100 °C), which is why hot liquid water at depth is expected in a hydrothermal system.


Table of reported Vilaflor data: depth of about 9,843 ft (3,000 m), temperatures above 212 °F and up to about 302 °F, pressure of almost 435 psi with measurement point not public, hot water at high pressure, possibly meteoric origin, €14.5 million in VIAGEO funding and two more wells planned.
Table 1. What has been reported at Vilaflor, by whom, and with what status

Boiling curve of pure water in °F and psi: at 435 psi water stays liquid up to about 453 °F, far above 212 °F at atmospheric pressure.
Figure 2. Boiling curve of pure water (IAPWS-IF97). Under pressure, water stays liquid well above 212 °F (100 °C). The point at 435 psi (30 bar) is a reference only, because the measurement point of the reported value is not public

5. What the Next Wells Have to Prove

Finding hot fluid and permeability is an important exploration result. A commercial geothermal development, however, needs sustainable flow at useful temperature and pressure over long periods, without unacceptable pressure depletion or premature thermal breakthrough.


That requires production and injectivity testing, pressure-transient analysis, stabilised temperature surveys, fluid sampling and chemical analysis and, once several wells are available, interference or tracer testing to understand reservoir connectivity. The two additional exploration wells planned by the project team will be important in determining whether the observed system is local or part of a larger connected reservoir.


Reinjection is likely to be central to any commercial development because it returns produced fluid to the subsurface and can support pressure maintenance. Injection strategy still requires careful reservoir engineering: poor connectivity assumptions or overly short producer-injector spacing can accelerate thermal breakthrough. In a fractured volcanic system, well placement is both a drilling and a reservoir-management decision.


6. Why it Matters for Islands and for Colombia

The energy context is important. According to La Gaceta de Canarias, fossil fuels still generate around 80% of the electricity consumed in the Canary Islands, and the promoters estimate that a first production phase could cut the islands' oil import bill by up to €130 million a year. Geothermal generation can provide firm output around the clock and uses relatively little land, characteristics that are particularly valuable in isolated island grids. Spain's Secretary of State for Energy said the project results will help shape the regulatory framework for future developments, while DISA has called for a regulated tariff framework for geothermal power.


Colombia has its own geothermal case to develop. The Colombian Geological Survey has identified 1,170 MWe of geothermal potential in 21 geothermal areas across the country's three mountain ranges, with high-temperature, or high-enthalpy, potential in volcanic zones and medium- and low-temperature, or medium- and low-enthalpy, potential in sedimentary basins. Those estimates still require confirmation through exploration drilling. The parallel with Tenerife is practical: deep geothermal projects must first absorb exploration risk, then prove temperature, permeability, fluid behaviour and commercial deliverability before development capital can follow.


7. Where Well Engineering Comes in

Geology and geophysics can identify where a geothermal system may exist, but wells provide the direct subsurface evidence needed to test the model. At depths around 9,843 ft (3,000 m) and temperatures above 212 °F (100 °C), the engineering challenges overlap strongly with oil and gas and deep groundwater-well practice: high-temperature drilling, lost circulation in fractured formations, wellbore stability, casing and cement design for thermal cycling, corrosion and scaling, pressure management, formation evaluation and long-term integrity.


That overlap is directly relevant to the PES portfolio. Power Energy Services publicly lists geothermal wells, deep and shallow water wells, piezometric monitoring wells, managed-pressure drilling and underbalanced drilling among its capabilities. Tenerife is a useful example of why groundwater knowledge, subsurface characterisation and pressure-aware well construction belong in the same technical conversation.


Bottom Line

The Vilaflor well is an important result for deep geothermal exploration in Spain. At about 9,843 ft (3,000 m), the project encountered heat, subsurface fluids and permeability together, with elevated pressure also reported. Preliminary geochemistry suggests that at least part of the fluid may be meteoric water that circulated deep into the volcanic system. The decisive work is still ahead: additional wells, production and injectivity testing, fluid chemistry and reservoir connectivity studies will determine whether the indications can support a commercial geothermal development. The subsurface data identify the opportunity, and sustained well performance will determine whether the resource can be developed.


Sources

1. MITECO, Joan Groizard highlights the great potential of the Canary Islands for renewable energy development, 16 Sep 2026.

2. ITER, Cabildo de Tenerife, Tenerife moves toward a new energy model with the discovery of geothermal potential, 17 Sep 2026.

3. Energías Renovables, Tenerife detects geothermal potential at 3,000 meters, 17 Sep 2026.

4. Atlántico Hoy, Caution after the finding that could change Tenerife's energy future, 11 Sep 2026.

5. Atlántico Hoy, Steam, permeability and pressure: the possible treasure more than 3,000 meters below Vilaflor, 16 Sep 2026.

6. La Gaceta de Canarias, Tenerife geothermal well reaches 3,000 meters with temperatures above 150 degrees, 16 Sep 2026.

7. ThinkGeoEnergy, Geothermal drilling in Tenerife reports high-temperature resource at 2300 meters depth, 14 Sep 2026.

8. Colombian Geological Survey, The subsurface and geosciences: keys to diversifying Colombia's energy mix, 29 May 2024.

9. Power Energy Services & Consulting Solutions, corporate capabilities.

10. Robit, Drilling into Tenerife's geothermal future, 6 Aug 2026.

11. Tenerife Weekly, Specialists from 20 nations seek additional geothermal energy beneath Tenerife following the discovery of an initial reserve, 11 Sep 2026.


Comments


bottom of page